DAS wired addressable fire alarm · Control panels
DAS-FACP-A324/xxAddressable fire alarm control panel DAS-FACP-A324 (2–10 loops, 324 devices/loop)
DAS-series addressable fire alarm panel from Tan Vien for large projects, expandable from 2 to 10 loops.
- 324 devices per loop, loop cable up to 2,000 m
- 4.3-inch color LCD
- Surge protection on the power supply and on each loop
Manufacturer's original documentation: DAS wired fire alarm catalogue (Tan Vien, 10/2026)
https://drive.google.com/file/d/1ESKG2ecYTZwIFTBWwFDQ2YItTvfPyMFM/view?usp=sharing
Schematic diagram of the DAS dedicated addressable fire alarm system connections
DAS-FACP-A324/xx addressable fire alarm control panel provides an intelligent, purpose-built addressable fire alarm solution, designed and manufactured to meet demanding project requirements such as: durable, stable operation in special environments — places with high humidity and corrosion resistance; fast, intuitive fire detection management for large-scale fire alarm systems with many devices. Expandable from 2 to 10 loops, with each loop able to connect and control 324 devices (detectors or modules alike), the product flexibly controls complex fire protection systems such as: high-pressure water mist fire suppression systems, smoke extraction systems, opening/closing of fire doors, fire curtains, and large, complex zoned fire protection systems such as thermal power plants, chemical plants and large industrial parks….
https://drive.google.com/file/d/1ESKG2ecYTZwIFTBWwFDQ2YItTvfPyMFM/view?usp=sharing
Technical specifications
- 4.3-inch color LCD with a resolution of 480*272.
- Number of loops of the control panel: 2 to 10 loops.
- Number of devices per loop: 324 devices (detectors or modules alike)
- Maximum loop cable length: 2000 m
- The panel has built-in surge protection on the power line.
- The panel has built-in surge protection circuits for each loop of the fire alarm panel.
- Integrated Ethernet communication circuit with RJ45 connection to link up to 254 fire alarm panels, with no limit on transmission distance.
- Integrated CAN communication interface: can connect 60 panels in the same system.
- The panel can place calls and send fire alarm SMS messages to designated phone numbers.
- The panel supports 5-status SMS messaging: fire alarm, fault, incident alarm …
- The panel allows loop wiring in a branched (T-tap) topology combined with short-circuit isolator modules, ensuring stable operation, isolating the faulty or burnt section from the system, and keeping the other zones operating normally.
- The panel integrates 6 to 22 forced-control units, each consisting of 2 on/off control buttons and a status indicator, to control peripheral equipment: fire pump systems, smoke exhaust fan systems, zone-selection fire suppression valves….
- The panel integrates single control buttons to control peripheral equipment as required by any system: rolling shutters, fire curtains.
- The panel integrates a printer that lists events.
- The fire alarm panel uses non-polarized device technology, which makes installation, operation and maintenance of the system convenient.
- The fire alarm panel has a large programming command library, making system programming convenient and simple and meeting most control requirements, similar to a PLC (Programmable Logic Controller).
DAS-FACP-A324/xx technical specifications
| Model | DAS-FACP-A324/xx |
|---|---|
| Type | Multi-loop addressable fire alarm control panel |
| Number of loops | 2 to 10 loops (catalogue); versions A324/2, /4, /6, /8 are in the published price list |
| Capacity | 324 devices per loop (detectors or modules) |
| Maximum loop length | 2,000 m |
| Display | 4.3-inch color LCD, 480 × 272 |
| Connectivity | Ethernet RJ45 (links up to 254 panels); CAN (60 panels) |
| Phone calls, SMS | Fire alarm phone calls and SMS to designated numbers; 5-status SMS |
| Control console | 6 to 22 forced-control units (on/off + status LED) for pumps, fans, valves…; single control buttons for rolling shutters and fire curtains |
| Protection | Surge protection on the power line and on each loop |
| Printer | Integrated event printer |
| Main power | 187–242 VAC / 50 Hz |
| Backup power | 24 VDC (2 × 12 VDC / 14 Ah batteries) |
| Output current | Up to 10 A @ 24 VDC |
| Environment | 0 °C to +55 °C; humidity ≤ 95 % |
DAS