Fire alarm system · Fire alarm system – CCC (previous models)
JTY-GD-A30KEConventional photoelectric smoke detector
Sanjiang conventional photoelectric smoke detector, 2-wire non-polarized bus, passed fire-protection equipment inspection.
- Compensates for drift caused by dust, temperature and humidity; sensor faults are reported to the panel
- Circuit board with triple-layer coating
- 304 stainless steel contacts, non-polarized
Original manufacturer documents: Specifications & instructions (EN) · Sanjiang CCC Catalogue (EN) · CCC system installation guide (EN) · CCC Catalogue – Vietnamese translation (part 1) · CCC Catalogue – Vietnamese translation (part 2)
The product has passed fire-protection equipment inspection. A microchip samples in real time and processes the data to calculate smoke density.
Compensates for drift from dust accumulation, temperature and humidity, and detects sensor faults (fault information is reported to the control panel)
- Non-polarized conventional photoelectric smoke detector
- The non-polarized detector contacts make installation of the fire alarm system very convenient.
- The detector's circuit board has a 3-layer waterproof, corrosion-resistant coating, so it works well in damp and marine environments.
- Light weight: 75g
- Contacts made of 304 stainless steel, durable in hot and humid weather such as Vietnam's and suitable for installation in coastal areas.
- Very low monitoring current, below 50 µA; alarm current 1–20 mA.
- Works well up to an installation height of 12m; protection area per the applicable design codes and standards (in Vietnam: TCVN 5738:2021).
- Compact, modern and attractive shape: diameter 105mm, height 43mm
- Housing made of high-grade ABS plastic.
Technical specifications
- Non-polarized conventional photoelectric smoke detector
- The non-polarized detector contacts make installation of the fire alarm system very convenient.
- The detector's circuit board has a 3-layer waterproof, corrosion-resistant coating, so it works well in damp and marine environments.
- Light weight: 75g
- Contacts made of 304 stainless steel, durable in hot and humid weather such as Vietnam's and suitable for installation in coastal areas.
- Very low monitoring current, below 50 µA; alarm current 1–20 mA.
- Works well up to an installation height of 12m; protection area per the applicable design codes and standards (in Vietnam: TCVN 5738:2021).
- Compact, modern and attractive shape: diameter 105mm, height 43mm
- Housing made of high-grade ABS plastic.
Technical specifications JTY-GD-A30KE
| Model | JTY-GD-A30KE |
|---|---|
| Type | Conventional photoelectric smoke detector |
| Standards | GB 4715-2005 |
| Operating voltage | Loop 24 V |
| Operating current | Monitoring < 50 µA; alarm 1–20 mA (depending on the loop current-limiting resistor) |
| Wiring | 2-wire non-polarized bus; used together with an input module and the fire alarm panel |
| Base | DZ-A16K |
| Indicator | Red: 1 flash every 6 seconds when monitoring, 2 flashes every 6 seconds on sensor fault, steady on in alarm |
| Installation height | ≤ 12 m |
| Protection area | Per the applicable design codes and standards (in Vietnam: TCVN 5738:2021) |
| Environment | −10 °C to +50 °C; humidity ≤ 95 % (40 °C ± 2 °C, non-condensing) |
| Dimensions | Ø105 mm, height 43 mm (with base) |
| Weight | Approx. 75 g (with base) |
Related products
JB-QBL-A104E
Fire alarm control panel
Price on request
JB-QBL-A108E
Fire alarm control panel
Price on request
JB-QBL-A220E
Fire alarm control panel
Price on request
JTY-GD-A30E
Point-type Photoelectric Smoke Detector
Price on request
JB-QBL-DK520E
fire equipment power supply monitoring panel
Price on request